NEMA34 Closed Loop Integrated Stepper Motor

RS485 and Pulse Type
$101.00
*
Qty:
(This product has a limit set to 10000 item(s) per order)


The IG23 series integrated motor is the perfect combination of drive and stepper motor,
which perfectly integrates stepper motor and drive technology, also built in 1000 line encoder,
it can save installation space, Simultaneously saving design and production costs,
supporting RS485 and TTL communication.

ItemSpecifications
Stepper Motor SizeNEMA34
Encoder type1000 line encoder
Working voltage24~80VDC,  18~60VAC
Driver Current0.5-6.5A
Velocity rangeUp to 3000RPM
Control MethodRS485,  Pulse& Direction, Twin-Pulse, 
I/O,   Built-in Program
Torque value3.5 -12.5Nm
Nonvolatile storageConfiguration parameters are stored in FLASH inside the MCU
DI and DO
2 DI, 1 DO
ProtectionOvervoltage, undervoltage, overcurrent, open winding, position deviation

Digital Input (2/3) Receive 3.3-24VDC
Digital Output(1)Maximum withstand voltage of 30V,
Maximum input or output current 30mA


Motor Parameters

Model No.length
mm L
Shaft length
mm
Shaft dia.
mm
Phase current
A
Resistance
Ω
inductance
mH
Hold torque
N.m
Inertia
g.cm²
Weight
g
IG344580321460.53.64.519502900
IG2346598321460.634.56.525003400
IG3485118321460.54.28.528004100
IG34125151321460.634.712.549505600


     Wiring Diagram:
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    1. Pulse Type Integrated Stepper Motor, Terminal definition.
     

    Terminal Definition

    TerminalNameDescription
    1V24~60VDC
    2V-GND
    3X0 (PU )Optoelectronic isolation, differential,
    High level can directly receive 3.3-24VDC, with a minimum pulse width of 2us,
    The maximum pulse frequency is 400KHz, which can be used as a universal input port for Pulse/Direction
    4X0-(PU-)
    5X1 (DR )
    6X1-(DR-)
    7X2(EN )Optoelectronic isolation, differential,
    High level can directly receive 3.3-24VDC, with a minimum pulse width of 100us,
    The maximum pulse frequency is 10KHz, which can be used as a universal input port for Enable
     8X2(EN-)
    9Y0 (AL )The default alarm output port can detect the driver alarm status and provide feedback to the main station. Other functions can be set through communication
    10Y0-(AL-)
    11Y1(EX )The default In-place output , Other functions can be set through communication
    12Y1(EX-)

    Set Micro-step by SW1, SW2, SW3 and SW4:


    SW5=OFF:  Pulse & Direction;   SW=ON: Twin Pulse mode.
    SW6=OFF:  CW direction;  SW6=ON:  CCW direction.

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    2. RS485 Type Integrated Stepper Motor, Terminal definition.

    Terminal Definition

    TerminalNameDescription
    1V24~60VDC
    2V-GND
    3X0 (PU )Optoelectronic isolation, differential,
    High level can directly receive 3.3-24VDC, with a minimum pulse width of 2us,
    The maximum pulse frequency is 400KHz, which can be used as a universal input port for Pulse/Direction
    4X0-(PU-)
    5X1 (DR )
    6X1-(DR-)
    7X2 (EN )
     8X2-(EN-)
    9Y0 (AL )The default alarm output port can detect the driver alarm status and provide feedback to the main station. Other functions can be set through communication
    10Y0-(AL-)
    11485ARS485 Communication port, default baud rate is 115200
    12485B

    Set Device ID for RS485 integrated Stepper Motor by SW1 ~ SW5:


    SW6 is used to set the terminal resistance;   OFF=0 ohms; ON=120 ohms

    CRC Check routine by C# :

    Uint16 Funct_CRC16(unsigned char * puchMsg, Uint16 DataLen)
    {
    Uint16 i,j,tmp;
    Uint16 crcdata=0xFFFF;
    for(i=0;i<DataLen;i )
    {

    crcdata=(*puchMsg)^crcdata;
    puchMsg ;
    for(j=0;j<8;j )
    {
    tmp=crcdata&0x0001;
    crcdata=crcdata>>1;
    if(tmp){
    crcdata=crcdata^0xA001;
    }
    }
    }
    returncrcdata;
    }

    Software Modbus Poll 

    Software Step-Config
    1. Extract the zip file,  open CommFile and Click Step-Config.exe


    2. Right Click Modbus_485, and Click Property:
         
    3. Click Property ComNN, Choose COM port, Baud rate and click Save and OK.
       

    4. Start to use software control the RS485 Integrated stepper motor by below buttons:


    RS485 Stepper Motor Controller Manual 

    ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
    Block Diagram:

    2  Input signals can directly receive 3.3-24V DC levels at high levels, Max. frequency of 400KHZ.
    X0:  pulse input, IO start/stop, limit, direction, universal input.
    X1  pulse input, IO start/stop, limit, direction, universal input.
    ...

    1 Output signal, maximum withstand voltage 30V, maximum input or output current 30mA
     Y0 : alarm output, universal output, and factory default alarm output.
     
    LED indicator and status: