NEMA8 Closed Loop Integrated Stepper Motor

Pulse and TTL Type
$80.00
*
Qty:
(This product has a limit set to 10000 item(s) per order)


The IG6 series integrated motor is the perfect combination of drive and stepper motor,
which perfectly integrates stepper motor and drive technology, also built in 1000 line encoder,
it can save installation space, Simultaneously saving design and production costs,
supporting RS485 and TTL communication.

ItemSpecifications
Stepper Motor SizeNEMA8
Encoder type1000 line encoder
Working voltage6~24VDC
Driver Current0.2-1.5A
Velocity rangeUp to 3000RPM
Control MethodRS485,  Pulse& Direction, Twin-Pulse, 
I/O,   Built-in Program
Torque value0.08 - 0.24Nm
Nonvolatile storageConfiguration parameters are stored in FLASH inside the MCU
DI and DO
2/3 DI,  1 DO
ProtectionOvervoltage, undervoltage, overcurrent, open winding, position deviation

Digital Input (2/3) Receive 3.3-24VDC
Digital Output(1)Maximum withstand voltage of 30V,
Maximum input or output current 30mA


Motor Parameters
NEMA11 integrated Stepper Motor:

Model No.length
mm L
Shaft length
mm
Shaft dia.
mm
Phase current
A
Resistance
Ω
inductance
mH
Hold torque
N.m
Inertia
g.cm²
Weight
g
IG8002281840.6630.0152.580
IG8004381841.03.21.30.043.3100

 Wiring Diagram:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
1. Pulse Type NEMA6 Integrated Stepper Motor, Terminal definition.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
2. TTL Type NEMA11 Integrated Stepper Motor, Terminal definition.

Terminal Definition

TerminalNameDescription
1V6 ~ 24VDC
2V-GND
3X0(PU)Optoelectronic isolation, differential,
High level can directly receive 3.3-24VDC, with a minimum pulse width of 2us,
The maximum pulse frequency is 400KHz, which can be used as a universal input port Pulse/Direction
4X1(DR)
5X2(EN)Optoelectronic isolation, differential,
High level can directly receive 3.3-24VDC, with a minimum pulse width of 100us,
The maximum pulse frequency is 10KHz, which can be used as a universal input port for Enable
6COM-Input common ground
7Y0 (AL )The default alarm output port can detect the driver alarm status and provide feedback to the main station. Other functions can be set through communication
8Y0-(AL-)

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Block Diagram:

2  Input signals can directly receive 3.3-24V DC levels at high levels, Max. frequency of 400KHZ.
X0:  pulse input, IO start/stop, limit, direction, universal input.
X1  pulse input, IO start/stop, limit, direction, universal input.
...

1 Output signal, maximum withstand voltage 30V, maximum input or output current 30mA
 Y0 : alarm output, universal output, and factory default alarm output.
 
LED indicator and status:


more Information on detail, please feel free to contact me  

Write Review